sxsphinxstack

Skills / Working / Create configurations in PartMode

Working Design skill

Create configurations in PartMode

Create, switch, and verify named PartMode configurations driven by parameter overrides.

Build named variants that reproduce exact geometry from one editable model. Read https://partmode.com/help#configurations-and-drawings before exporting a configuration-controlled result.

Required connection

This skill is operating guidance, not a PartMode login or tool connection. Before an agent continues, confirm that it can list PartMode MCP resources and tools. If it cannot, stop and use $connect-partmode-to-an-agent: create or sign in to an account at https://partmode.com/account with an account name and passphrase, create the least-powerful suitable agent key, store the one-time secret as PARTMODE_AGENT_KEY, and configure Codex with:

``sh codex mcp add partmode --url https://partmode.com/mcp --bearer-token-env-var PARTMODE_AGENT_KEY ``

Restart the agent after adding the server. A browser-local project also requires a signed-in PartMode tab and visible approval; server-headless work requires an edit key created with the explicit headless grant. Never simulate CAD work from these instructions or claim completion without exact settled evidence returned by the connected PartMode tools.

Boundaries

  • Keep shared design intent in the base model and override only documented inputs.
  • Use unique configuration names that communicate the variant, not row numbers alone.
  • Do not edit a table-driven dimension ad hoc when the task requires activating a stored configuration.
  • Verify every configuration independently; one successful row does not validate all rows.

Procedure

  1. Identify the independent parameters that define each variant and the dimensions, features, or body state that must remain common.
  2. Create and validate the base parameters with $use-parameters-in-partmode. Choose a known-good default before adding variants.
  3. Choose ManageConfigurations and create a named configuration for each approved parameter set. Record units in the values or governing contract.
  4. Activate one configuration at a time and wait for the kernel and document to settle. Do not switch again while a rebuild is pending.
  5. Inspect the active name, effective parameter values, body count, exact health, and critical measurements. Record failures against the specific configuration.
  6. Switch away and back to a tested configuration. Confirm it reproduces the same canonical document and exact geometry for unchanged inputs.
  7. Export or draw only after activating and reinspecting the intended configuration. Include the configuration name in the delivery manifest.